Perle IDS-409

Managed Industrial Ethernet Switch
9 port Compact DIN Rail Switch

Perle IDS-409
6509_28909.png
6509_28910.gif
  • PropertiesProperties
  • DescriptionDescription
  • Further InformationFurther Information
  • PDFPDF
  • 9 port 10/100/1000Base-T ( RJ45 ) for Gigabit and Fast Ethernet devices
  • IP Manageability, VLAN and resiliency management
  • Digital inputs for generation of alerts
  • Compact, corrosion resistant case attaches to a standard DIN Rail
  • Redundant dual power input 12/24/48 VDC, 24 VAC
  • Out-of-band management via RJ45 or USB serial ports
  • Programmable Controller safety and Hazardous Location Certification
  • -40 to 75C industrial operating temperature ( XT Models )
The IDS-409 is a 9 port Managed Ethernet Switch that can operate in industrial 10/100/1000-Base-T environments providing advanced performance and enabling real-time deterministic network operation.
Perle IDS-409 Industrial-grade Ethernet Switches are designed to stand up to extreme temperatures, surges, vibrations, and shocks found in industrial automation, government, military, oil and gas, mining and outdoor applications.



The simple Plug and Play installation available in Perle’s Fast Setup feature gets your Ethernet devices networked immediately. The familiar Command Line Interface ( CLI ), via in-band Telnet or the out-band serial console port, will be appreciated by CCNA ( Cisco Certified Network Associate ) and CCNP ( Cisco Certified Network Professional ) trained engineers.
The IDS-409 can be managed with an IPv6 address and supports a comprehensive set of management functions, such as P-Ring, management VLAN, QoS, RMON, N:1 port mirroring and local alert log.


These rugged fan-less switches that are hardened to provide superior reliability in -10 to 60°C.
In addition, every component on every industrial (XT) model has been designed and tested to handle operating temperatures between -40 and 75C.



ProdGrafik

IDS-206 Industrial Managed DIN Rail Switch Features

Simple deployment

  • Zero-touch discovery using Dynamic Host Control Protocol (DHCP), Perles "Fast Setup"
    for first time installation, provides simple deployment in Ethernet environments


Resiliency

  • STP and RSTP protocols for fast recovery.
  • Perles P-Ring protocol for fastconvergence in ring topologies
  • IDS-205 Industrial Managed DIN Rail Switch Features


Managebility

  • Web Device Manager, Telnet, SNMP and Perle’s PerleView NMS for centralized management
  • In-band management via RJ45 port
  • Use an IPv4 or IPv6 address
  • Removable MicroSD flash for conifuration files and firmware backup and restoration


Rugged design for harsh environments

  • Corrosion resistant case
  • Programmable Controller Safety certified
  • Certified for hazardous locations
  • Extended industrial temperature models


Reliable operation

  • Fan-less, no moving parts
  • Dual power input. Connect to separate power sources for redundancy.
    • Reverse polarity protection
    • Overload current protection
  • Handles vibration and shock conditions found in industrial environments


Real-time Ethernet performance

  • Fast wire-speed , store and forward switching
  • Auto-sensing for speed and duplex
  • Auto-mdi/mdix-crossover works with straight and crossover cables


Features

Performance Features 
Port Auto-sensing Auto-sensing of port speed and auto-negotiation of duplex on all switch ports for optimizing bandwidth
Auto MDI/MDIX Medium-dependent interface crossover ( Auto-MDIX ) capability on 10/100 and 10/100/1000 mbps interfaces that enables the interface to automatically detect the required cable type ( straight thru or crossover ) and to configure the connection appropriately
802.3x flow control IEEE 802.3x flow control on all ports. ( The switch does not initiate pause frames )
Storm Control Storm control prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on one of the physical interfaces. A LAN storm occurs when packets flood the LAN, creating excessive traffic and degrading network performance. Storm Control enables limits to be placed on broadcast, multicast and unicast traffic
Static MAC Addressing This feature enables the manual configuration of the MAC addresses on a per port basis. Flooding is prevented by retaining MAC entries across a reboot of the switch.
Port Blocking Port Blocking provides the ability to block the flooding of unknown layer 2 unicast and multicast traffic on an Interface
IPV4 IGMP Snooping Internet Group Management Protocol ( IGMP ) constrains the flooding of multicast traffic by dynamically configuring Layer 2 interfaces so that multicast traffic is forwarded to only those interfaces associated with IP multicast devices.
IGMPv1, v2, v3, IGMP snooping querier mode, IGMP report suppression, topology change notification and robustness variable features are supported
Port Quick Disconnect In some network environments, it is desirable to move an Ethernet from one switch port to another and have the device come on-line quickly. The Port Quick Disconnect feature if enabled, provides an immediate age-out of the MAC addresses learned on the port when the port status changes from a link-up to a link-down state
Manageability Features 
Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch. Unlike competitive products, Java applet technology is not required or used
Command Line Interface
( CLI )
A familiar text-based Command Line Interface that is based on accepted industry standard syntax and structure. Ideal for CCNA and CCNP trained engineers, this interface is available via in-band Telnet or the out-band serial console port
SNMP Manage the switch with an snmp compatible management station that is running platforms such as HP Openview or Perle’s PerleVIEW NMS. SNMP V1 and V2C
PerleVIEW PerleVIEW is Perle’s SNMP-based network management system that provides a view of the network with a large scale of Perle networking devices.
IPv6 Manage with an IPv4 or IPV6 address
DHCP Client Auto-Configuration Automates configuration of switch information such as IP address, default gateway, hostname and Domain Name System ( DNS ) as well as TFTP server names. Firmware and configuration file locations are provided through options 54, 66, 67, 125 and 150
DHCP Relay DHCP Relay is used for forwarding requests from DHCP clients when they are not on the same physical subnet. As a DHCP relay agent the switch operates as a Layer 3 device that forwards DHCP packets between clients and servers.
DHCP Option 82 Insertion Normally used in metro or large enterprise deployments DHCP Option 82 insertion is used to provide additional information on “physical attachment” of the client. As per RFC 3046, option 82 enables additional pre-defined information to be inserted into the DHCP request packet ( for DHCP Servers that support this option )
LLDP LLDP-Link Layer Discovery Protocol as per IEEE 802.1AB is a neighbor discovery protocol that is used for network devices to advertise information about themselves to other devices on the network. This protocol runs over the data-link layer, which allows two systems running different network layer protocols to learn about each other ( via TLVs – Type-Length-Value )
File Download Firmware can be transferred via TFTP, HTTP or via insertion of a microSD card. Text-based files that can be created or edited by common text editors.
Availability and Redundancy Features 
Spanning Tree Protocol
( STP )
IEEE 802.1D now incorporated in IEEE 802.1Q-2014, STP prevents bridge loops and the broadcast radiation that results from them.
Rapid Spanning Tree Protocol ( RSTP ) Interoperable with STP, RSTP ( IEEE 802.1w ) takes advantage of point-to-point wiring and provides rapid convergence of the spanning tree. Reconfiguration of the spanning tree can occur in less than 1 second
P-Ring P-Ring provides an easy to use method for configuring a ring network using standard spanning tree protocols.
Prevents a switch loop scenario in a ring topology.
Link Standby A link recovery feature using a primary and backup link. Provides a simple alternative to spanning tree protocols for link redundancy
VLAN Features
VLAN Range Up to 256 VLANS across a VLAN ID range of 1 to 4000
VLAN Interfaces Perle switches provide the ability to configure management VLAN interfaces. This enables network administrators to access the switch’s management interface from separate VLAN networks
Quality of Service ( QoS ) and Class of Service ( CoS ) Features 
Classification IP ToS/DSCP and IEEE 802.1p CoS
Congestion Avoidance Weighted Fair Queuing or Strict Queuing
Egress Queues and scheduling
  • 4 traffic class queues per port
  • output queue mapping
  • DSCP to output queue mapping
Monitoring Features 
Port Mirroring N:1 Port Mirroring is a method of monitoring network traffic. With port mirroring enabled, the switch sends a copy of one or more ports to a predefined destination port. Selection of Transmit, Receive frames or both can be made
RMON RMON statistics provided for statistics, history, alarms and events for network monitoring and traffic analysis
Syslog Facility for logging systems messages to an external SYSLOG server
Alert Log Facility for logging systems messages locally
Traceroute Layer 2 traceroute to identify the path that a frame takes from source to destination
Power Supply Monitoring Provides the status of power supplies of the switch
Alarm Processing The switch can monitor global switch conditions as well as individual ports.
These alarms can be configured to send messages to ;
  • an internal log file
  • external Syslog server
  • SNMP trap server
  • An external alarm device such as a bell, light or other signaling device via the switch’s built-in dry contact alarm relay
Global Status Monitoring Alarms
  • Dual power supply alarm
Port Status Monitoring Alarms
  • Link Fault Alarm ( IE loss of signal )
  • Port not forwarding alarm
  • Port not operating alarm ( failure upon start up tests )
  • FCS Bit error rate alarm
Alarm Relay When enabled, energizes the built-alarm relay triggering an external alarm circuit such as a bell, light or other signaling device according to alarm conditions set
Management and Standards 
IEEE Standards IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X) and 100Base-X
IEEE 802.3ab for 1000Base-T
EEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1AB LLDP
SNMP MIB Objects IEEE8021-PAE-MIB
NTPv4-MIB
IEEE8021-SPANNING-TREE-MIB
SYSAPPL-MIB
LLDP-EXT-MED-MIB
SNMP-COMMUNITY-MIB
LLDP-EXT-MED-MIB
IGMP-STD-MIB
IEEE8021-MSTP-MIB
Q-BRIDGE-MIB
LLDP-EXT-DOT3-MIB
IF-MIB
RSTP-MIB
DIFFSERV-DSCP-TC
LLDP-EXT-DOT1-MIB
IEEE8021-TC-MIB
LLDP-MIB
RMON2-MIB
ENTITY-MIB
P-BRIDGE-MIB
PERLE-LOGIN-MIB
PERLE-ALERT-MIB
PERLE-IP-SSH-MIB
PERLE-IP-PROTOCOLS-MIB
PERLE-USER-MIB
PERLE-SMI
PERLE-MAC-NOTIFICATION-MIB
PERLE-SYSINFO-MIB
PERLE-LINKSTANDBY-MIB
PERLE-AAA-MIB
perle-AAA.MIB
PERLE-IPV6-MIB
PERLE-LOGGING-MIB
PERLE-VLAN-MIB
PERLE-IF-MIB
PERLE-ENTITY-VENDORTYPE-OID-MIB
PERLE-ERR-DISABLE-MIB
PERLE-SWITCH-PLATFORM-MIB
PERLE-ENVMON-MIB
PERLE-TIME-MIB
PERLE-PTP-MIB
PERLE-P-RING-MIB
PERLE-SNMP-MIB
PERLE-FILE-TRANSFER-MIB
PERLE-SWITCH-GLOBAL-MIB
PERLE-BOOT-MIB
PERLE-PRODUCTS-MIB
PERLE-BANDWIDTH-CONTROL-MIB
PERLE-IP-TELNET-MIB
PERLE-GVRP-MIB
PERLE-PORT-SECURITY-MIB
PERLE-DHCP-SERVER-MIB
PERLE-GARP-MIB
PERLE-ARCHIVE-MIB
PERLE-NTP-MIB
PERLE-SSL-MIB
PERLE-IGMP-MIB
PERLE-ACL-MIB
PERLE-POE-MIB
PERLE-RELOAD-MIB
PERLE-ENTITY-ALARM-MIB
PERLE-IPV6-NEIGHBOR-MIB
PERLE-DOT1X-AUTH-MIB
PERLE-TC
PERLE-DHCP-CLIENT-MIB
PERLE-LINE-MIB
PERLE-ARP-MIB
PERLE-GMRP-MIB
PERLE-MLD-MIB
PERLE-IP-HTTP-MIB
PERLE-PORT-MONITOR-MIB
PERLE-SpTreeExtensions-MIB
PERLE-IP-MIB



< strong>Hardware Specs

Power 
Dual Power Input
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
12/24/48 VDC Nominal. ( 9.6 to 60 VDC)
24 VAC Nominal ( 18 to 30 VAC )
Power Connector
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
Maximum Current Consumption @24 vDC 0.68 amps
Maximum Power Consumption @24 vDC 16.3 watts
Overload Current Protection
Fused overload current protection
Reverse polarity protection
The positive and negative inputs can be reversed providing safe and simple power connectivity.
Access Ports 
RJ45
9 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
Ethernet isolation 1500 V
RJ45 Serial Console port
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
USB Serial Console port
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
Digital Inputs Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
Alarms  
  • NC (Normally Closed ) or NO ( Normally Open ) dry contact.
  • 1A @ 24V
Switch Properties 
Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow Control
Processing Type
Store and Forward
MAC Address Table Size
8K
VLAN ID range
1 to 4000
IGMP groups
1024
Packet Buffer Memory
1 Mbit
Indicators  
Power
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
System
Indicates whether the switch O/S is operating normally
RJ45 Ethernet
These integrated colored LEDs indicate link, activity and speed for each port.
Alarm
The alarm LED ( Red ) will be turned on under alarm conditions
P-Ring Master LED
Status of the P-Ring Master
Backup Network Coupling
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
External Configuration DIP Switches  
S2
When enabled, designates this switch as the Ring Master
S1
Activate Backup Coupling between 2 ring networks
Environmental Specifications 
MTBF 121,022 Hours
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
Operating Temperature Ranges
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
Storage Temperature Range
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
Operating Humidity Range
5% to 90% non-condensing
Storage Humidity Range
5% to 95% non-condensing
Maximum Heat Output 55.7 Btu/hr
Operating Altitude
Up to 3,048 meters (10,000 feet)
Chassis
Metal with an IP20 ingress protection rating
Din Rail Mountable
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
Product Weight and Dimensions 
Weight
1.5 kg
Dimensions
75 x 130 x 121mm
Packaging 
Shipping Weight
2.0 kg
Shipping Dimensions
170 x 260 x 70 mm
Standards and Certifications 
Safety
UL 60950-1
IEC 60950-1(ed 2); am1, am2
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
UL 62368-1
IEC 62368-1(ed 2)
EN 62368-1:2014
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
IEC 61010-1(ed.3), IEC 61010-2-201(ed.1)
EN 61010-1:2010
CE Mark
Emissions
FCC 47 Part 15 Class A
CISPR 32:2015/EN 55032:2015 (Class A)
EMC and Immunity
  • CISPR 24:2010/EN 55024:2010
  • IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 4kv, Air discharge +/- 8kv
  • IEC/EN 61000-4-3 (RS) : 80mhz to 1Ghz ; 10v/m, 1.4Gkz to 2.0ghz ; 5 v/m, 2.0ghz to 2.7 ghz ; 5 v/m
  • IEC/EN 61000-4-4 (EFT) : DC power line +/- 2kv, data line +/- 1kv
  • IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 1kv, Line/Earth +/- 2kv, data line /earth +/- 2kv
  • IEC/EN 61000-4-6 (CS) :150khz-80Mhz 10vrms
  • IEC/EN 61000-4-8 (Magnetic Field) :30 A/M
  • IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
Industrial Safety
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
Hazardous Locations ( Hazloc )
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 )
ATEX Class 1 Zone 2
EN 60079-0:2012+A11:2013 and EN 60079-15:2010
Environmental
Reach, RoHS and WEEE Compliant
Other
ECCN: 5A991
HTSUS Number: 8517.62.0050
5 year Warranty
Contents Shipped
  • Industrial Ethernet Switch with DIN Rail attachment
  • Terminal block
  • Installation guide


Customers who viewed this item also viewed
Accept all Reject Configure

This website uses cookies to provide the best possible experience. More information.